Gravity Fed Solutions

/Gravity Fed Solutions
Gravity Fed Solutions2019-01-09T10:43:06+00:00

WHOLE HOUSE SOLUTION

For gravity systems, our whole house solution is the most popular choice. Installing a pump next to the hot water cylinder, but after the vent pipe, will boost the flow rate for every tap, shower & application in the house.

Diagram 8.1 SP2B installed on gravity hot feed after the vent pipe.

Diagram 8.1 SP2B installed on gravity hot feed after the vent pipe.


PROTECTED FLOW SOLUTION

Sometimes there is just one tap, shower or application which is letting you down with poor flow rates & low pressure. The Shower Power Booster does not cavitate so you are able to install it on the feed which only supplies a specific tap or shower. This will not only improve the flow for the specific outlet, it will also maintain the flow even if other taps are being used in the home.

Diagram 8.2 SP2B installed after the vent pipe on a specific outlet.

Diagram 8.2 SP2B installed after the vent pipe on a specific outlet.


BALANCED FLOW SOLUTIONS

A single Shower Power Booster is sufficient for most installations. A good shower or tap mixer should be able to cope with pressure differentials of up to 4 to 1.

If your hot and cold supplies are both very low pressure, or your mixer struggles to balance pressures, then you may need to install a pump on both the gravity hot and cold feeds. This will not only improve all water outlets, but will also keep the system balanced.


WHOLE HOUSE BALANCED FLOW SOLUTION

Diagram 9.1 Two Automatic Pumps (SP22S) linked together and installed on Gravity Hot & Cold Feeds after the vent pipe and feeding the whole house.

Diagram 9.1 Two Automatic Pumps (SP22S) linked together and installed on Gravity Hot & Cold Feeds after the vent pipe and feeding the whole house.


PROTECTED FLOW BALANCED FLOW SOLUTION

Diagram 9.2 Two Automatic pumps (SP22S) linked together and installed on gravity hot and cold feeds after the vent pipe and feeding a specific outlet.

Diagram 9.2 Two Automatic Pump (SP22S) linked together an installed on gravity hot and cold feeds after vent pipe and feeding a specific outlet.


FLEXIBLE INSTALLATION

The Shower Power Booster can be installed anywhere within the house, including in a shower room and in the loft. Pumps do not cavitate or pull air in the vent pipe so you can install wherever is easiest to fit. If you are struggling to get two pumps close together or installing in different rooms you can still link them together using low voltage DC extension cables.

Diagram 10.1 Two automatic pumps (SP22S) linked together and installed on Gravity Hot & Cold Feeds after the vent pipe in the loft.

Diagram 10.1 Two Automatic Pumps (SP22S) linked together and installed on Gravity Hot & Cold Feeds after the vent pipe in the loft.

ProductsContact Us